Menu and settings
Hold K1 when output is zero to open the menu. The left digit is the item number and the right digit is its value. For example, 12 means item 1 is set to 2 seconds.
| Item | Right digit | Default display |
|---|---|---|
| 1 Throttle ramp | 1–5 seconds for a 0% to 100% ramp | 12 |
| 2 Enable delay | 0–8 seconds, with 0 skipping the countdown | 20 |
| 3 PWM frequency | 1 = 1 kHz, 2 = 20 kHz, 3 = 24 kHz. Used for duty-cycle PWM | 33 |
| 4 Output protocol | 0 = 50 Hz servo pulses, 1 = duty-cycle PWM | 40 |
| 5 Throttle source | 0 = knob, 1 = Hall throttle or pedal | 50 |
| 6 Direction mode | 0 = bidirectional, 1 = one direction. Used for 50 Hz servo pulses | 60 |
| 7 S1 contact type | 0 = normally open, 1 = normally closed | 70 |
- Press once to change the value. Double-press to move to the next item, wrapping from item 7 to item 1.
- Hold K1 on any item to save all changes and exit. Five seconds of inactivity discards the edits and exits.
88means the board must restart to apply new output settings. Output stays at the stop value until restart.99means saving failed and the previous settings are still active.- The Hall throttle and pedal use a calibrated range of 0.85–2.30 V. A reading below 0.65 V or above 2.60 V sends the stop signal.
- If an earlier V1.0 test build used fixed output levels, item 5 may initially show
52and output stays stopped. Select50or51and hold K1 to save.